Private
Public Access
0
0
Files
manual_slop/tests
ed 8957c9a5be fix(conftest): register atexit handler for non-blocking pool shutdown
Fixes the run_tests_batched.py hang that occurs after batch 4.
The original conftest (commit 52ea2693) stored _warmup_app_controller
at module scope for the entire pytest session. When pytest exits,
GC of the AppController triggers ThreadPoolExecutor.__del__ ->
shutdown(wait=True). If warmup hasn't fully completed by then, the
shutdown blocks indefinitely, causing the batched test runner to
hang at the subprocess.run boundary.

Fix: register an atexit handler that captures the _io_pool reference
directly (default argument) and shuts it down with wait=False. The
pool reference is captured by closure, surviving even after the
AppController is GC'd. shutdown() is idempotent so the subsequent
shutdown(wait=True) in __del__ is a no-op.

This is part of sub-track 4 (warmup notification) cleanup; the
conftest's wait_for_warmup behavior is preserved, only the
exit-hang is fixed.